diff options
-rw-r--r-- | sys-power/apcupsd/ChangeLog | 6 | ||||
-rw-r--r-- | sys-power/apcupsd/apcupsd-3.14.6.ebuild | 115 |
2 files changed, 5 insertions, 116 deletions
diff --git a/sys-power/apcupsd/ChangeLog b/sys-power/apcupsd/ChangeLog index 2cc1cd219437..049e33dead81 100644 --- a/sys-power/apcupsd/ChangeLog +++ b/sys-power/apcupsd/ChangeLog @@ -1,6 +1,10 @@ # ChangeLog for sys-power/apcupsd # Copyright 1999-2009 Gentoo Foundation; Distributed under the GPL v2 -# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/ChangeLog,v 1.61 2009/12/29 18:45:28 armin76 Exp $ +# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/ChangeLog,v 1.62 2009/12/29 18:47:52 flameeyes Exp $ + + 29 Dec 2009; Diego E. Pettenò <flameeyes@gentoo.org> + -apcupsd-3.14.6.ebuild: + Cleanup old version. 29 Dec 2009; Raúl Porcel <armin76@gentoo.org> apcupsd-3.14.7.ebuild: sparc stable wrt #295424 diff --git a/sys-power/apcupsd/apcupsd-3.14.6.ebuild b/sys-power/apcupsd/apcupsd-3.14.6.ebuild deleted file mode 100644 index 9184255b311c..000000000000 --- a/sys-power/apcupsd/apcupsd-3.14.6.ebuild +++ /dev/null @@ -1,115 +0,0 @@ -# Copyright 1999-2009 Gentoo Foundation -# Distributed under the terms of the GNU General Public License v2 -# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/apcupsd-3.14.6.ebuild,v 1.6 2009/11/18 18:36:15 armin76 Exp $ - -WEBAPP_MANUAL_SLOT="yes" -WEBAPP_OPTIONAL="yes" -inherit eutils webapp - -DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown" -HOMEPAGE="http://www.apcupsd.org/" -SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz" - -LICENSE="GPL-2" -SLOT="0" -KEYWORDS="~alpha amd64 ppc sparc x86 ~x86-fbsd" -IUSE="snmp usb cgi nls gnome" - -DEPEND=" - cgi? ( >=media-libs/gd-1.8.4 - ${WEBAPP_DEPEND} ) - nls? ( sys-devel/gettext ) - snmp? ( net-analyzer/net-snmp ) - gnome? ( >=x11-libs/gtk+-2.4.0 - >=dev-libs/glib-2.0 - >=gnome-base/gconf-2.0 )" -RDEPEND="${DEPEND} - virtual/mailx" - -pkg_setup() { - use cgi && webapp_pkg_setup -} - -src_compile() { - local myconf - use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=${MY_CGIBINDIR}" - if use usb; then - myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --with-dev= " - else - myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb" - fi - - # We force the DISTNAME to gentoo so it will use gentoo's layout also - # when installed on non-linux systems. - econf \ - --sbindir=/sbin \ - --sysconfdir=/etc/apcupsd \ - --with-pwrfail-dir=/etc/apcupsd \ - --with-lock-dir=/var/lock \ - --with-pid-dir=/var/run \ - --with-log-dir=/var/log \ - --with-nis-port=3551 \ - --enable-net --enable-pcnet \ - --with-distname=gentoo \ - $(use_enable snmp net-snmp) \ - $(use_enable gnome gapcmon) \ - ${myconf} \ - APCUPSD_MAIL=/bin/mail \ - || die "econf failed" - emake || die "emake failed" -} - -src_install() { - use cgi && webapp_src_preinst - - emake DESTDIR="${D}" install || die "installed failed" - rm -f "${D}"/etc/init.d/halt - - insinto /etc/apcupsd - newins examples/safe.apccontrol safe.apccontrol - - dodoc ChangeLog* ReleaseNotes - doman doc/*.8 doc/*.5 || die "doman failed" - - dohtml -r doc/manual/* || die "dodoc failed" - - use cgi && webapp_src_install - - rm "${D}"/etc/init.d/apcupsd - newinitd "${FILESDIR}/${PN}.init.2" "${PN}" || die "newinitd failed" - - if has_version sys-apps/openrc; then - newinitd "${FILESDIR}/${PN}.powerfail.init" "${PN}".powerfail || die "newinitd failed" - fi -} - -pkg_postinst() { - if use cgi; then - elog "If you are upgrading from a previous version, please note" - elog "that the CGI interface is now installed using webapp-config." - elog "/var/www/apcupsd is no longer present." - webapp_pkg_postinst - fi - - elog "" - elog "Since version 3.14.0 you can use multiple apcupsd instances to" - elog "control more than one UPS in a single box." - elog "To do this, create a link between /etc/init.d/apcupsd to a new" - elog "/etc/init.d/apcupsd.something, and it will then load the" - elog "configuration file at /etc/apcupsd/something.conf." - elog "" - - if [ -d "${ROOT}"/etc/runlevels/shutdown -a \ - ! -e "${ROOT}"/etc/runlevels/shutdown/"${PN}".powerfail ] ; then - elog 'If you want apcupsd to power off your UPS when it' - elog 'shuts down your system in a power failure, you must' - elog 'add apcupsd.powerfail to your shutdown runlevel:' - elog '' - elog ' \e[01m rc-update add apcupsd.powerfail shutdown \e[0m' - elog '' - fi -} - -pkg_prerm() { - use cgi && webapp_pkg_prerm -} |